ID badges: Hide | Show

Part 3AMENDMENTS TO COUNCIL REGULATION (EC) NO 428/2009

Amendments to Category 2 - Materials Processing

10.—(1) The section headed Category 2 - Materials Processing is amended as follows.

(2) In the section headed 2B Test, Inspection and Production Equipment—

(a)in entry 2B001.b.4.a.—

(i)for ““run-out”” substitute “‘run-out’”;

(ii)for ““camming”” substitute “‘camming’”;

(b)after entry 2B001.b.4.b., insert—

Technical Notes:
For the purposes of 2B001.b.4.a.:
1.‘Run-out’ (out-of-true running) is the radial displacement in one revolution of the main spindle measured in a plane perpendicular to the spindle axis at a point on the external or internal revolving surface to be tested (ISO 230-1:2012).
2.‘Camming’ (axial displacement) is axial displacement of one revolution of the main spindle measured in a plane perpendicular to the spindle faceplate, at a point next to the circumference of the spindle faceplate (ISO 230-1:2012).;

(c)in entry 2B001.c.2.c., for “4 m.” substitute “4 m;”;

(d)in the Note to entry 2B001.c.2.c., for length. substitute length; and for 1,1 μm. substitute 1,1 μm;;

(e)in entry 2B001.d., for “Electrical discharge machines” substitute “Electrical Discharge Machines”;

(f)in entry 2B002.d.—

(i)for “Magnetorheological finishing” substitute “‘Magnetorheological finishing’”;

(ii)for “Electrorheological finishing” substitute “‘Electrorheological finishing’”;

(g)in the N.B. at the end of entry 2B004, after “tooling” insert “,”;

(h)in entry 2B006.b.3.c—

(i)for “measurement uncertainty” substitute ‘measurement uncertainty’;

(ii)after 0,01°C; omit or;

(i)in the Note at the end of entry 2B006.d., for 2B006 substitute 2B006.a.;

(j)for entry 2B352.c., including the Technical Note, substitute—

c.Centrifugal separators as follows:
1.Centrifugal separators, capable of continuous separation without the propagation of aerosols, having all the following:
a.Flow rate exceeding 100 litres per hour;
b.Components of polished stainless steel or titanium;
c.One or more sealing joints within the steam containment area; and
d.Capable of in-situ steam sterilisation in a closed state;
2.Single-use centrifugal separators, in which all components that come in direct contact with the substances being processed are disposable or single-use.
Technical Note:
Centrifugal separators and single-use centrifugal separators include decanters.;

(k)after entry 2B352.i., insert—

j.Peptide synthesizers that are partly or entirely automated and capable of generating peptides at a ‘system synthesis scale’ of 1 mmol or greater.
Technical note:
‘System synthesis scale’ denotes the maximum amount of peptide (mmol) that can be produced by the instrument using the largest compatible reaction vessels. For multiple peptides produced in parallel, this is the sum of the largest compatible reaction vessels.
N.B.: For other chemical reaction vessels or reactors, see 2B350..

(3) In the section headed 2D Software, in Note 2 to entry 2D002—

(a)for See 2D001 and 2D003 for substitute For;

(b)after in 2B002 insert , see 2D001 and 2D003.

(4) In the section headed 2E Technology—

(a)in the Note to entry 2E001 for coordinate measurement machines substitute Coordinate Measuring Machines (CMM);

(b)in the Technical Note to the table (Deposition techniques) that appears after entry 2E301—

(i)in paragraph a—

(aa)for N.B.1 substitute N.B.1. ;

(bb)for N.B.2 substitute N.B.2. ;

(cc)for N.B.3 substitute N.B.3.;

(ii)in paragraphs d and f—

(aa)for N.B.1 substitute N.B.1.;