SCHEDULES
SCHEDULE 11DEEMED MARINE LICENCE UNDER THE 2009 ACT—GENERATION ASSETS
PART 2CONDITIONS
Design parameters
schedule 11 part 2 paragraph 1 1.—(1) The total number of wind turbine generators comprised in the authorised scheme must be no more than 90 having a total rotor swept area of no more than 4.45 square kilometres.
(2) Subject to sub-paragraph (3), each wind turbine generator forming part of the authorised scheme must have—
schedule 11 paragraph 1 2 a (a)a height of no more than 325 metres when measured from LAT to the tip of the vertical blade;
schedule 11 paragraph 1 2 b (b)a rotor diameter of no more than 295 metres;
schedule 11 paragraph 1 2 c (c)a distance of no less than 22 metres from MHWS to the lowest point of the rotating blade; or
schedule 11 paragraph 1 2 d (d)a distance of no less than 830 metres from the nearest wind turbine generator in all directions,
and the authorised scheme will comprise turbines of a uniform height and rotor diameter.
(3) The reference in sub-paragraph (2)(d) to the location of a wind turbine generator is a reference to the centre point of that wind turbine generator.
(4) Wind turbine generator foundation structures forming part of the authorised scheme must have either a monopile foundation, or multileg foundation.
(5) Wind turbine generator—
schedule 11 paragraph 1 5 a (a)multileg foundations employing pin piles forming part of the authorised scheme must have—
schedule 11 paragraph 1 5 a i (i)no more than 4 legs per foundation;
schedule 11 paragraph 1 5 a ii (ii)no more than 4 pin piles per foundation; and
schedule 11 paragraph 1 5 a iii (iii)a pin pile diameter of no greater than 4.5 metres;
schedule 11 paragraph 1 5 b (b)multileg foundations with suction bucket must have—
schedule 11 paragraph 1 5 b i (i)no more than 4 legs per wind turbine generator;
schedule 11 paragraph 1 5 b ii (ii)a suction bucket diameter of no more than 15 metres; and
schedule 11 paragraph 1 5 b iii (iii)a suction bucket penetration of no more than 25 metres; and
schedule 11 paragraph 1 5 c (c)monopile foundation forming part of the authorised scheme may have a diameter no greater than 13.5 metres.
(6) The total volume of scour protection for wind turbine generators (where necessary) must be no more than 1,215,000 cubic metres with a maximum footprint of 405,000 square metres.